TL;DR
29 CFR 1910.147 requires a written energy control program, machine-specific lockout procedures, trained authorized and affected employees, and an annual program audit. Employers must provide locks and tags at no cost to workers. The maximum serious-violation penalty is $16,131 as of 2025, and lockout tagout has ranked in OSHA's top 5 most-cited standards for over a decade.
What is 29 CFR 1910.147 and who does it cover?
29 CFR 1910.147 is OSHA's Control of Hazardous Energy standard, almost always called the lockout tagout standard. It covers the servicing and maintenance of machines and equipment where unexpected energization, startup, or release of stored energy could hurt a worker. OSHA estimates the standard protects roughly 3 million workers who perform servicing work, plus another 39 million in industries that use the equipment. [1]
The standard applies to general industry employers. Construction, maritime, and agriculture have their own rules. If your employees change tooling, clear jams, lubricate parts, adjust belts, or do anything that requires bypassing a guard or putting a body part near a point of operation, 1910.147 applies. Plenty of small employers assume it only touches heavy manufacturing. It doesn't. A bakery, a printing shop, a car wash with a conveyor, a restaurant with a commercial meat grinder: all covered.
The one carve-out people misuse is the "normal production operations" exclusion. The idea sounds simple: if a task is part of normal production and the machine's guarding gives adequate protection, 1910.147 may not apply. But OSHA has issued multiple letters of interpretation making clear that clearing jams, even routine ones, is not normal production. If the guard has to be opened or bypassed, you're in 1910.147 territory. [2]
What are the exact elements a written energy control program must include?
1910.147(c)(4)(i) requires a written energy control program. The regulation itself doesn't hand you a numbered checklist of elements, which is exactly why so many small employers write something too thin and get cited. Read across the full standard and a defensible written program has to cover all of the following:
- A statement of purpose and scope (what equipment and what tasks are covered at your facility)
- The rules and techniques for controlling hazardous energy
- Roles defined: authorized employees (those who lock out), affected employees (those who operate the machine), and other employees (anyone else in the area)
- How the employer enforces compliance with the program
- Rules for tagout-only situations and the extra steps required when a lock can't be applied
- A process for lockout by a single authorized employee versus a group lockout procedure
- How outside contractors are coordinated (your program must inform contractors of your energy control procedures and verify theirs are equally effective) [3]
- A procedure for shift or personnel changes so energy control stays continuous
- A description of how machine-specific procedures are developed and where they're kept
- The annual audit process
The written program is the umbrella document. It does not replace machine-specific procedures. That's the mistake I see most often: employers write a solid general program and have no equipment-specific procedures at all.
Want to skip the blank-page problem? The SafetyFolio lockout tagout program generator builds a written program and a procedure template library in about 15 minutes, matched to your equipment list. Any qualified person can also write this from scratch using the standard itself. Both work.
When do you need machine-specific lockout procedures, and what goes in them?
1910.147(c)(4)(ii) requires documented, specific energy control procedures for each piece of equipment unless the employer can show the machine has no potential for stored or residual energy, has a single energy source that's easily identified and isolated, and that isolating and locking out that source fully de-energizes the machine. Very few machines in a real facility clear all three bars. So write the procedures. [1]
Each equipment-specific procedure has to document:
| Required element | What it means in practice |
|---|---|
| Intended use of the procedure | Name the machine and the type of service task |
| Steps to shut down the equipment | Sequence matters for some equipment |
| Steps to isolate energy | Every source: electrical, pneumatic, hydraulic, mechanical, thermal, chemical, gravity |
| Steps to apply lockout/tagout devices | Which devices, on which points |
| Steps to release stored energy | Bleed lines, block parts, discharge capacitors |
| Steps to verify de-energization | Test before anyone touches anything |
The verification step is one inspectors zero in on. A procedure that says "disconnect power" but never tells anyone to confirm the machine won't start is deficient. 1910.147(d)(6) requires a test of the equipment after applying energy controls to confirm the isolation actually worked. [1]
For group lockout, each authorized employee applies their own lock to a hasp. Eight people on a machine means eight locks. The machine can't be re-energized until every lock comes off, each one removed by the person who put it there. This is non-negotiable, and it's a common citation target in facilities that lean on a single "control lock" shortcut.
Who needs lockout tagout training, and what exactly must training cover?
Training requirements under 1910.147(c)(7) depend on the employee's role. Three tiers, three different depths of training.
Authorized employees, the workers who actually apply locks and tags, must be trained to recognize hazardous energy sources, understand the type and magnitude of energy in their workplace, and know the methods to isolate and control it.
Affected employees, the people who operate equipment that gets locked out, must be trained to understand the purpose of the energy control program and to leave locks and tags alone. They don't apply lockout devices, but they need to know why nobody removes a device except the authorized employee who placed it.
Other employees, meaning anyone else working in an area where lockout is used, must be trained to recognize when a procedure is in effect and to stay clear of the equipment.
Retraining is triggered when there's reason to believe an employee doesn't understand the program, when a deviation shows up, or when equipment, processes, or the energy control program itself changes. The standard sets no fixed calendar interval beyond those triggers. But the annual program inspection (next section) often surfaces training gaps that should send someone back for retraining. [1]
Documentation is required. 1910.147(c)(7)(iv) says the employer must certify that training has happened. That means names, dates, and the subject of the training, at a minimum. A sign-in sheet with a training outline attached does the job. Keep those records. If OSHA shows up and a worker says they never got lockout training, written documentation is your only defense. [10]
For how to structure training records across every program, more than lockout, see our broader OSHA training guide.
What does the annual lockout tagout program audit require?
1910.147(c)(6) requires an annual inspection of the energy control program. It's one of the most skipped requirements in the standard and a reliable citation target.
The audit has two parts. First, a review of the written energy control procedures. Second, a certification by the inspector that the audit happened, listing the date, the equipment inspected, the names of the authorized employees involved, and the inspector's name. [1]
The inspector must be an authorized employee, but doesn't have to be an outside auditor or a paid consultant. A qualified employee at your facility who performs lockout can run the audit. The catch: the inspector can't be the same person whose work is being inspected. If you have exactly one authorized employee, you have a problem, because they can't audit themselves. A manager or a second employee trained to the authorized level has to conduct it.
For equipment where tagout is used instead of lockout, the inspection must include a review with each authorized and affected employee of their responsibilities under the program. That's a hands-on walkthrough, more than paperwork.
So what does a defensible annual audit look like? Pick a representative sample of your machine-specific procedures. Watch authorized employees perform lockout on that equipment. Confirm the written procedure matches what they actually do. Document any gaps, fix them, and certify the inspection in writing. Done right, this takes a few hours. Skipping it can cost up to $16,131 per serious citation. [4]
What lockout tagout hardware and devices does the standard require?
1910.147(c)(1) requires that energy-isolating devices be capable of being locked out if they were installed or replaced on or after January 2, 1990. For older equipment that can't be locked out, tagout procedures may be used, but only with supplemental steps that provide safety equivalent to lockout. [1]
The standard doesn't name brands or exact specs. It sets broad requirements. Locks and tags must be:
- Durable enough to survive the environment where they're used (tags must be standardized, and OSHA requires warnings like "Do Not Operate")
- Standardized within the facility by color, shape, or size
- Substantial enough to resist removal without excessive force
- Identifiable, so each lock or tag traces back to the authorized employee who applied it
Personal locks should be individually keyed. No master key, except for a documented emergency removal procedure spelled out in your written program. Each authorized employee gets their own lock and their own key. The employer pays for this equipment. No cost to the worker.
Hasps, lockout blocks, breaker lockouts, pneumatic lockout valves: all common. What you actually need depends on your equipment. A shop with 200-amp panels and pneumatic presses needs a different kit than a food plant running mixers and conveyors. Walk your equipment, find every energy source on each machine, and buy hardware that fits those exact isolation points. A lock that doesn't physically fit the disconnect handle doesn't satisfy the standard. It's just a lock in a drawer.
What are the steps in the actual lockout tagout procedure sequence?
1910.147(d) lays out the sequence, and every machine-specific procedure you write should map to these steps, in this order.
1. Prepare for shutdown. Identify all energy sources and the type and magnitude of each. Gather the required lockout devices. 2. Notify affected employees. Tell the people who operate the machine that it's coming out of service and why. 3. Shut down the equipment. Use the normal stopping procedure. 4. Isolate the energy. Operate the energy-isolating device (disconnect switch, valve) to the off or closed position. 5. Apply lockout or tagout devices. Each authorized employee applies their own lock to the energy-isolating device. 6. Release or restrain stored energy. Bleed pneumatic or hydraulic pressure, discharge capacitors, block parts that could drop under gravity, let thermal energy dissipate. 7. Verify de-energization. Try to start the machine with its normal controls. Confirm with a meter on electrical equipment. Check pressure gauges on hydraulic and pneumatic systems. Then return the controls to off. 8. Perform the service work.
Restoration runs in reverse, with two additions: clear all tools and materials, and confirm everyone is clear before locks come off and the machine goes live. The authorized employee who applied the lock is the one who removes it. Nobody else.
1910.147(e)(3) does allow someone other than the authorized employee to remove a lock under narrow conditions: only after the employer verifies the authorized employee has left the facility, takes all reasonable steps to reach them, and informs them before they return to work. Narrow. Don't turn it into a habit.
When is tagout-only allowed instead of lockout?
Lockout wins by default. If the energy-isolating device can take a lock, use a lock. Tagout-only is allowed only when the equipment physically cannot be locked out, which usually means an older machine whose isolating device has no hasp or lockout capability.
When tagout is used, 1910.147(c)(3) requires the employer to show the tagout program gives full employee protection equivalent to lockout. That means at least one additional safety measure beyond the tag: pulling a fuse, blocking a control switch, opening a second disconnecting device, or removing a valve handle. A tag alone is never enough. It's a warning, and warnings can be ignored or removed. [1]
Tags must carry a warning against energizing the equipment. OSHA's regulation calls for language like "Do Not Start, Do Not Open, Do Not Close, Do Not Energize, Do Not Operate." The tag must make clear that no one removes it except the authorized employee, and that it is not a physical restraint.
Buying new equipment? Make sure the disconnects are lockable. It's cheap at purchase time and it erases a whole category of compliance headaches later.
How does OSHA enforce 1910.147 and what do violations actually cost?
Lockout tagout has landed in OSHA's top 5 most-cited standards every year for more than a decade. In federal fiscal year 2023, 1910.147 generated 2,554 violations, one of the highest citation counts across the entire general industry rulebook. [4]
Here are the penalty ceilings as of 2025:
| Violation type | Maximum penalty per violation |
|---|---|
| Serious | $16,131 |
| Other-than-serious | $16,131 |
| Willful or repeated | $161,323 |
OSHA adjusts these for inflation every year. The $16,131 figure is the current maximum; actual penalties get scaled by employer size, good faith, and history. Small employers with fewer than 25 employees can see reductions of up to 60% before any good-faith adjustment. [9]
What triggers an inspection? A worker injury involving machine energy is the most common. A complaint from a current or former employee is another. OSHA also runs programmed inspections in high-hazard industries like fabricated metals, plastics, and food processing, where lockout violations show up often. [8]
Inspectors hunt for four things above all: the written program, machine-specific procedures, training records, and annual audit certifications. Miss any of the four and citations follow. And the human stakes are real. The Bureau of Labor Statistics tracks fatal and nonfatal injuries from equipment servicing, and hazardous energy releases kill workers every year across manufacturing and food processing. [5] That's why OSHA leans on this standard so hard.
For how OSHA inspections actually run and what to expect on the day, the OSHA basics guide walks through it.
How do you handle lockout tagout for contractors and outside service workers?
1910.147(f)(2) covers outside personnel. When contractors or outside service techs do work covered by the standard at your facility, you have two obligations. First, inform them of your energy control procedures. Second, verify that their procedures give protection equivalent to yours before you let them touch your equipment. [3]
In practice, that means getting a copy of the contractor's lockout tagout program before work starts, reviewing it, and documenting that review. If their program doesn't meet 1910.147, you can't let them work until the gap is closed. "They have their own program" is no defense if a contractor gets hurt on your equipment.
The reverse applies too. When your employees work at a customer's facility, they're bound by that facility's energy control procedures. Your written program should say how your people handle that.
On a multi-employer worksite, coordination is required. Both employers' programs have to be compatible, and employees on both sides have to understand who controls what. Put that coordination in writing before anyone starts.
What's the difference between a lockout tagout procedure and a lockout tagout program?
People mix these up constantly, and it opens real compliance gaps.
The written energy control program is the facility-level policy document. It describes your overall approach: the roles (authorized, affected, other), the general rules, how procedures get developed, how training runs, how audits happen, how contractor situations are handled. It's the "how we manage energy control at this company" document.
Machine-specific energy control procedures are the step-by-step instructions for a single piece of equipment or a closely related group. They tell the authorized employee exactly which disconnect to pull, which valve to close, which stored energy to release, and how to confirm the machine is safe before touching it.
You need both. A program without procedures is a safety policy that says "drive carefully" and never mentions a single traffic rule. An inspector who asks for your lockout tagout program, and gets handed a stack of equipment procedures, has only half an answer.
The lockout tagout overview article on this site covers the conceptual split in plain language if you're building from scratch.
Does 1910.147 apply to electrical work, or does NFPA 70E cover that?
Genuine point of confusion, and the short answer is both may apply. They cover different risks.
29 CFR 1910.147 controls hazardous energy for servicing and maintenance, including electrical energy, to prevent unexpected energization. 29 CFR 1910.333 covers electrical safety-related work practices for employees working on or near energized conductors. NFPA 70E is a consensus standard (not an OSHA regulation) that OSHA often cites as guidance for the 1910.333 requirements. [7]
For an electrician de-energizing a panel to swap a breaker, 1910.147 governs the lockout. For an electrician working near energized conductors where lockout isn't feasible, 1910.333 and NFPA 70E govern the work practices and PPE.
The two standards work together. If you're writing an energy control program for a facility with electrical maintenance staff, reference both. Our hazard communication written program guide is a useful model for how multi-standard written programs get structured.
OSHA's take on "energized electrical work" and how it splits from lockout scenarios is laid out in the 1910.333 standard and in multiple letters of interpretation available at osha.gov. [2]
How do you build a lockout tagout program without hiring a consultant?
You don't need a consultant. You need time, accurate equipment information, and a working knowledge of 1910.147. Here's the sequence I'd follow.
Start with a walk-through. Walk every piece of equipment that gets serviced or maintained. For each one, list every energy source: electrical, pneumatic, hydraulic, mechanical, chemical, thermal, gravitational. This inventory is the foundation for your whole procedure library.
Write the written program first. This is your policy document. OSHA publishes a model program at osha.gov that you can adapt. It isn't perfect for every facility, but it hits the required elements. [6] Tailor it to your roles and equipment.
Write machine-specific procedures second. Use the six-element structure from the standard: shutdown, isolation, lockout application, stored energy release, verification, return to service. Write them for a competent employee who knows the machine but is following the procedure for the first time.
Train your authorized and affected employees. Document it: names, dates, content covered.
Run your first program audit. Even on a brand-new program, walking through a few procedures with authorized employees will expose gaps before OSHA does.
To speed up the program-writing step, SafetyFolio's generator walks through your equipment list and outputs a written program plus procedure templates that meet 1910.147, usually in about 15 minutes. After that, your job is to verify the procedures against your real equipment, which no software can do for you.
Want the broader OSHA picture? The OSHA 30 training course covers energy control inside its general industry curriculum.
Frequently asked questions
Does OSHA 1910.147 apply to small businesses?
Yes. 1910.147 applies to all general industry employers regardless of size. There's no small-business exemption. Employers with fewer than 25 employees may get reduced penalties (up to 60% off) if cited, but the program, procedure, and training requirements are identical to a large plant's. If your employees service or maintain equipment, the standard covers you.
What is the annual lockout tagout audit and who can conduct it?
1910.147(c)(6) requires an annual inspection of energy control procedures, conducted by an authorized employee who did not perform the work being reviewed. The audit reviews each procedure, involves the authorized employees who use it, and gets certified in writing with the date, equipment reviewed, employees involved, and the inspector's name. You don't need an outside auditor. A qualified internal employee works.
Can a supervisor remove an employee's lockout lock if they leave the facility?
Only under a specific, documented procedure. 1910.147(e)(3) lets an employer remove a lock placed by an absent employee only after verifying the employee has left the facility, taking all reasonable steps to contact them, and making sure they're informed before returning to work. This must be in your written program. Routine removal of another person's lock is a serious violation.
What's the penalty for not having a written lockout tagout program?
A missing written program is typically cited as a serious violation under 1910.147(c)(4)(i), with a maximum penalty of $16,131 per citation as of 2025. If OSHA finds the absence willful, or the employer has been cited before, the maximum jumps to $161,323. Penalties get adjusted for employer size, good faith, and compliance history.
Does lockout tagout apply to cord-and-plug equipment?
1910.147 exempts cord-and-plug connected equipment where unplugging the cord is the energy-isolating step and the authorized employee keeps exclusive control of the plug throughout the work. If you unplug the machine and hold the plug in your hand while you service it, lockout under 1910.147 isn't required. If someone else could reinsert the plug, you need lockout or a plug retention device.
How often does lockout tagout training need to be refreshed or repeated?
1910.147 sets no fixed retraining interval. Retraining is triggered when there's reason to believe an employee doesn't understand the program, when deviations show up, or when equipment, energy sources, or procedures change. The annual audit often surfaces training gaps that should trigger retraining. Many employers train annually anyway as a practical baseline, which is reasonable.
What counts as stored energy and how do you control it?
Stored energy is any energy that remains after the primary source is isolated. Examples: capacitor charge in electrical systems, compressed air or hydraulic fluid under pressure, springs under tension or compression, elevated components that could drop under gravity, and residual heat in process equipment. Controlling it means actively bleeding, discharging, blocking, or restraining that energy, then verifying it's gone before touching the machine.
What's the difference between an authorized employee and an affected employee under 1910.147?
An authorized employee is trained and assigned to apply and remove lockout or tagout devices and perform the service work. An affected employee operates or uses the equipment being worked on. Affected employees must be trained to recognize lockout procedures and understand they can't remove lockout devices. A worker can be both depending on the task, which the training documentation must cover.
Do contractors have to follow my facility's lockout tagout procedures?
Yes. Under 1910.147(f)(2), outside contractors must be informed of your energy control procedures, and you must verify their program provides equivalent protection. If their program is deficient, they can't start work. Their lockout procedures and yours have to be compatible. Document the coordination before work begins. You remain responsible for contractor safety on your equipment.
What equipment is exempt from machine-specific lockout procedures?
Equipment is exempt from a written machine-specific procedure only if all three conditions are met: no potential for stored or residual energy, a single energy source that's easily identified and isolated, and lockout of that source completely de-energizes the machine. Most industrial equipment fails at least one condition. When in doubt, write the procedure. The cost is low; the citation risk of skipping it is not.
What OSHA citations are most common in a lockout tagout inspection?
Inspectors most often cite: missing or inadequate written program (1910.147(c)(4)), missing machine-specific procedures (1910.147(c)(4)(ii)), no annual audit certification (1910.147(c)(6)), inadequate training or no training documentation (1910.147(c)(7)), and failure to verify de-energization before servicing (1910.147(d)(6)). These five make up the large majority of 1910.147 violations across industries.
Can I use a tagout tag instead of a lock if a lock won't fit the equipment?
Only if the equipment physically cannot be locked out. Tagout-only is a last resort and requires additional safety measures beyond the tag itself, such as removing a fuse, opening a secondary disconnect, or removing a valve handle. The tagout system must provide protection equivalent to lockout. Document this in your written program and train employees specifically on the extra steps required.
How does group lockout work when multiple employees are on the same machine?
Each authorized employee applies their own personal lock to a lockout hasp on the energy-isolating device. The machine stays locked out until every person removes their own lock. No single control lock held by one person for the group. Ten people on the job means ten locks on the hasp. The written program must describe the group lockout procedure, including how coordination and shift changes are handled.
Sources
- OSHA, 29 CFR 1910.147 Control of Hazardous Energy (Lockout/Tagout): Full text of 1910.147 including requirements for written program, machine-specific procedures, training, annual audit, and the lockout sequence
- OSHA, Letters of Interpretation: 1910.147: OSHA letters of interpretation clarifying scope, the normal production operations exclusion, and tagout-only applicability
- OSHA, 1910.147(f)(2) Outside Personnel: Employer must inform outside contractors of energy control procedures and verify contractor procedures provide equivalent protection
- OSHA, Top 10 Most Cited Standards FY 2023: 1910.147 generated 2,554 violations in FY2023 and consistently ranks in OSHA's top 5 most-cited standards
- Bureau of Labor Statistics, Injuries, Illnesses, and Fatalities: BLS data on fatal and nonfatal injuries from equipment servicing and hazardous energy releases
- OSHA, Control of Hazardous Energy (Lockout/Tagout) topic page and model program: OSHA's model energy control program and compliance guidance for employers building a written program
- OSHA, 29 CFR 1910.333 Electrical Safety-Related Work Practices: 1910.333 governs work on or near energized electrical conductors, separate from but compatible with 1910.147 lockout requirements
- OSHA, Enforcement Directives: OSHA enforcement directives and programmed inspection guidance for 1910.147, including what inspectors examine and how citations are classified
- OSHA, OSHA Penalties: Current maximum penalties: $16,131 serious/other-than-serious, $161,323 willful or repeated, adjusted annually for inflation, with size-based reductions
- OSHA, Training Requirements in OSHA Standards (Publication 2254): OSHA training certification requirements for 1910.147 including documentation of employee name, date, and subject matter