TL;DR
OSHA's Hearing Conservation Amendment (29 CFR 1910.95) requires annual audiometric testing for any worker whose 8-hour average noise exposure hits 85 dB(A) or higher. You need a baseline audiogram within 6 months of enrolling someone in the hearing conservation program, then a test every year after. Skipping it is one of OSHA's regularly cited general industry violations, with serious penalties up to $16,550 per instance.
Which OSHA standard actually covers audiometric testing?
The rule is 29 CFR 1910.95, OSHA's Occupational Noise Exposure standard. The testing piece lives in the Hearing Conservation Amendment, which took effect in 1983 and added structured testing, training, and recordkeeping on top of the older noise rule. Before that amendment, the standard only asked for engineering controls and hearing protectors. The amendment built a full monitoring and medical surveillance program around them.
The standard applies to general industry. That covers manufacturing, fabrication, woodworking, food processing, and most shop environments you can name. Construction runs on a separate noise rule at 29 CFR 1926.52, and it doesn't carry the same hearing conservation requirements. Run a construction operation and a machine shop under one roof and you've got a real question about which workers fall under which standard.
For a plain-English look at osha and how its standards are organized, that background helps when you sit down to read the CFR itself.
What noise level triggers the audiometric testing requirement?
The trigger is an 8-hour time-weighted average of 85 decibels on the A-weighted scale, written 85 dB(A). OSHA calls this the action level. Once any employee's exposure reaches or passes it, that person goes into the hearing conservation program: audiometric testing, training, and access to hearing protectors [1].
The permissible exposure limit (PEL) sits higher, at 90 dB(A) TWA, and the two numbers do different jobs. The PEL is the ceiling you can't exceed without controls. The action level is the earlier warning line that starts the surveillance program. A worker can measure 87 dB(A) TWA, safely under the PEL, and still be owed annual audiograms by law.
OSHA uses a 5-dB exchange rate. Every 5 dB of increase cuts the allowed exposure time in half. So 90 dB(A) is fine for 8 hours, 95 dB(A) for 4 hours, 100 dB(A) for 2 hours, and down from there. NIOSH recommends a stricter 3-dB exchange rate and a recommended exposure limit of 85 dB(A), but OSHA's legal standard still runs on the 5-dB rate [2].
One practical note. If your shop is genuinely quiet except for one loud machine running 45 minutes a day, that might not push the TWA to 85. But most production shops with metal cutting, grinding, pressing, or pneumatic tools blow past it. Haven't measured yet? Assume you're over.
How do you measure employee noise exposure to know if testing is required?
You measure with noise monitoring. Section 1910.95(d) requires it whenever there's reason to believe exposures may reach the action level [1]. That's a wide trigger. If the work is loud enough that you'd raise your voice to be heard at arm's length, you should monitor.
Two tools do the work. A sound level meter gives you a snapshot of the decibel level at one spot and one moment. A dosimeter rides on the employee through the whole shift and rolls every exposure into a single TWA. Dosimetry is the better bet for people who move around, run different machines, or switch tasks. OSHA requires dosimeters to use slow response and A-weighting settings [1].
You can hire an industrial hygienist, which usually costs $500 to $2,000 for a small shop depending on headcount and how complicated the space is. Some state programs run through OSHA's On-Site Consultation Program will do it free for small businesses [3]. The results decide who goes into the hearing conservation program. Keep the records.
Remonitor when production changes, when equipment changes, or when a new employee starts in an area you haven't checked lately. You don't have to remeasure every year if conditions hold steady. You do have to reassess the moment there's reason to think exposures shifted.
What exactly does audiometric testing involve and who can perform it?
An audiogram is a hearing test that measures how well a person hears tones at set frequencies: 500, 1000, 2000, 3000, 4000, and 6000 Hz. It happens in a booth or room quiet enough to meet the background noise limits in Appendix D of 29 CFR 1910.95. The employee wears headphones and signals when each tone comes through. Results plot on a chart showing thresholds in each ear at each frequency [1].
Who runs it matters. OSHA allows the test to be done by a licensed or certified audiologist, an otolaryngologist (an ear, nose, and throat physician), or a physician. Trained technicians can run it too, as long as they work under the supervision of one of those professionals. Mobile testing vans that pull up to your facility are common in manufacturing areas and are perfectly legitimate, provided they meet OSHA's oversight requirements.
The standard also allows microprocessor audiometers that test automatically, as long as they meet Appendix C. Those can drop the per-test cost for larger shops.
The baseline audiogram (the first one) must come after at least 14 hours away from workplace noise. In practice that means testing first thing Monday morning before the week starts, or having the employee wear hearing protectors for the 14 hours beforehand. Annual audiograms carry no 14-hour rule, though plenty of programs still handle them the same way for consistency [1].
When does the baseline audiogram have to happen?
Within 6 months of the employee's first exposure at or above the action level. One exception: if you use a mobile van program, the deadline stretches to 1 year, but the employee has to wear hearing protectors from the 6-month mark to the 12-month mark [1].
The timing trips up more shop owners than you'd think. Hire someone in January, drag the baseline out to October, and you've already broken the standard. Inspectors check this during a records audit.
The baseline is also your reference point for everything that follows. Every annual audiogram gets compared back to it to see whether the employee has lost real hearing. That comparison is the whole point of the program.
What is a standard threshold shift and why does it matter?
A standard threshold shift (STS) is defined in 29 CFR 1910.95(g)(10) as an average hearing change of 10 dB or more at 2000, 3000, and 4000 Hz in either ear, measured against the baseline audiogram [1]. When an annual audiogram shows an STS, OSHA requires specific follow-up.
You have to notify the employee in writing within 21 days of confirming the STS. You have to make sure they have properly fitted hearing protectors and are actually wearing them. If they weren't wearing protectors before, now they must. If they already were, you refit and retrain. And if occupational noise caused or worsened the shift, you have to weigh whether stronger engineering controls or better protectors are needed [1].
OSHA lets you age-correct the data using the tables in Appendix F. Age correction backs out the natural hearing loss that comes with getting older, separate from noise damage on the job. Applying it can lower the count of apparent STS findings. Using it is your call, but you have to apply it consistently.
An STS is also recordable on the OSHA 300 log when it's work-related and the total hearing level is 25 dB or more above audiometric zero (averaged at 2000, 3000, and 4000 Hz) in the affected ear [4]. That's a separate determination from simply having an STS. Not every STS lands on the 300 log, but many do. The incident report rules tie straight into this call.
The number is exact. A 10 dB average shift at those three frequencies is the precise line OSHA draws, and it's held since the 1983 amendment.
How often do annual audiograms have to happen?
Once a year. OSHA doesn't name a calendar date, but the test has to happen at least every 12 months after the baseline. Most shops set them near the same time each year, which makes comparison cleaner and keeps the gap from slipping past 12 months.
Miss a year and you can't just shrug and pick back up the next one. You've got a recordkeeping gap, and if the employee developed a threshold shift during that stretch, you lost your chance to catch it and act. The real cost is quiet: an undetected STS means the hearing damage keeps going unchecked.
Some owners ask whether they can drop annual testing once everyone wears protectors faithfully. No. Hearing protectors don't retire the testing requirement. The program runs as long as exposures sit at or above the action level [1].
What hearing protectors are required and how does attenuation work?
Section 1910.95(i) requires employers to provide hearing protectors, free of charge, to every employee exposed at or above the 85 dB(A) action level. For workers at or above the 90 dB(A) PEL, wearing them is mandatory, not optional [1].
Protectors have to knock exposure down to at least 90 dB(A) when worn. If a given protector doesn't get you there, you need a better one. OSHA recommends derating the Noise Reduction Rating printed on the package, because real-world protection runs consistently below the lab-tested NRR. The common method: subtract 7 from the NRR, then divide by 2, to estimate field attenuation [5].
Employees get to pick from at least one earmuff and one formable earplug. If someone has a known or suspected middle ear condition, a physician should evaluate them before you settle on a protector type. Not common, but it's in the standard.
For a worker who's already had an STS, OSHA raises the bar. Their protector has to bring TWA exposure below 85 dB(A), more than below 90. That stricter number often means moving from plugs to muffs, or stacking a muff over a plug in the loudest spots [1].
What training do employees need under the hearing conservation standard?
Annual training for everyone in the hearing conservation program. It has to cover three things: how noise affects hearing, the purpose and use of hearing protectors, and the purpose and procedures of audiometric testing [1].
It doesn't have to be fancy. A 20-minute session with a short handout or slide deck hits the mark. What it does have to be is documented. Inspectors will ask for training records. Have names, dates, and topics covered.
Training happens on company time at no cost to the employee. In person, online, or video all work, as long as there's a record. OSHA's Training Guidelines for the Hearing Conservation Amendment, published in the Federal Register, spell out what counts as adequate content [6].
Building this as part of a bigger safety program? The osha training framework applies here too. Hearing conservation training tends to get walled off from the rest of your safety training, which is a mistake. Fold it into the same toolbox talks that cover other hazards and people actually remember it.
What records does your shop have to keep and for how long?
Two separate retention clocks run under 29 CFR 1910.95(m).
Noise exposure measurement records: keep for 2 years. Audiometric test records: keep for the full length of the affected employee's employment [1]. That second one carries weight. If someone works for you for 20 years, their audiogram records have to survive all 20. Once they leave, you're off the hook for keeping them, but not a day before.
Each audiogram record has to include the employee's name and job classification, the date of the audiogram, the examiner's name and certification, the date of the last audiometer calibration, and the employee's most recent noise exposure measurement [1].
Calibration is its own trap. Acoustic calibration has to run before each day of use. Exhaustive calibration has to run at least annually by a certified technician, with records kept. A poorly calibrated audiometer turns your audiograms into worthless paper, legally and medically.
Using an outside vendor? Make your service contract say who holds the records and how you get copies. Some vendors keep them on your behalf, which is fine, but you need documented access. If that vendor closes its doors, you still need the data.
Keeping all of this straight across multiple employees, multiple years, and third-party vendors is exactly where small shops fall apart. If you're building your written safety program from scratch, SafetyFolio's program generator walks you through the hearing conservation module alongside the rest of your required written programs in one session.
What does OSHA's hearing conservation program cost a small shop?
Nobody has perfectly clean data on this for small businesses, but the pieces are easy enough to price out.
Noise monitoring: $500 to $2,000 for a professional survey, or free through your state's OSHA On-Site Consultation Program [3].
Baseline and annual audiograms: mobile vendors usually charge $25 to $60 per employee per year for group visits. An audiologist's office may run $75 to $150 per test. For a 10-person shop, annual testing might land at $250 to $600.
Hearing protectors: disposable foam earplugs cost $0.10 to $0.50 each. Reusable earmuffs run $10 to $40 a pair. No fixed replacement schedule, just swap them when they're worn out or stop fitting right.
Training: run it internally and the cost is basically staff time. Third-party training modules run $10 to $30 per employee.
All in, a 10-person shop might spend $600 to $1,500 a year once the initial monitoring is behind you. That's a rounding error next to a citation. OSHA's maximum penalty for a serious violation is $16,550 per violation as of 2024, and each affected employee can count as a separate one [7].
What are the most common OSHA citations for hearing conservation violations?
OSHA cites hearing conservation failures often. The deficiencies inspectors keep finding: no noise monitoring at all, missing baseline audiograms for new hires, audiograms run without the 14-hour noise-free pre-test period, no follow-up after a standard threshold shift, no training documentation, and audiometers that were never calibrated [8].
The baseline timing miss is probably the most common in small shops, because it demands action within 6 months of hire and that deadline slips easily when HR and safety duties aren't clearly assigned to anyone.
Skipping STS follow-up is the one that goes worst, both medically for the employee and legally for you. OSHA treats it as an ongoing violation. Every month that passes without corrective action is another month of penalty exposure stacking up.
During an inspection, the compliance officer will typically want your noise exposure records, your roster of enrolled employees with their baseline and most recent audiogram dates, your STS follow-up documentation, your training records, and proof of audiometer calibration. Having all of it in one binder or folder speeds the inspection along and signals that you run the program on purpose, not by accident.
Do state OSHA plans have different audiometric testing requirements?
Twenty-two states and two territories run their own OSHA-approved plans covering private employers [9]. A state plan has to be at least as effective as federal OSHA, which means it can be stricter but never weaker.
In practice, most state plan states track the federal hearing conservation standard almost word for word. California's Cal/OSHA (Title 8, Section 5097) is the one to watch. It adds some provisions around audiogram timing and physician review that reach a bit past federal OSHA [10]. Washington's program carries supplementary guidance too.
In a state plan state, read your state's version of the noise standard before you assume federal 1910.95 tells the whole story. The state standards usually sit on the state labor department's website. The federal OSHA site lists every state plan state and links to their programs [9].
The same goes for hazard communication and lockout tagout. State plans layering modest extra requirements on top of federal standards is a pattern that shows up across many rules.
What's the written hearing conservation program requirement?
29 CFR 1910.95 doesn't use the phrase 'written program' the way the Hazard Communication standard does, but it effectively requires one. The rule tells you to establish and maintain an audiometric testing program, which in any real sense means documenting your procedures: who gets tested, when, by whom, how you track STS findings, how you notify employees, and how you pick and hand out hearing protectors.
Compliance officers look for a documented program description when they inspect. A shop with a clear written procedure, even a plain one, sits in far better shape than a shop running on memory and verbal instructions.
The written program should name someone responsible for running hearing conservation. That person doesn't have to be an audiologist, but they need to know the requirements and have the authority to enforce them. In a 5-person shop, that's probably you. In a 50-person shop, it's your safety coordinator or HR manager.
Frequently asked questions
Does the audiometric testing rule apply to part-time employees?
Yes. The trigger is noise exposure level, not employment status. If a part-time employee's time-weighted average exposure hits 85 dB(A) or more during whatever hours they work, they go into the hearing conservation program, audiometric testing included. There's no exemption based on hours worked per week or per year.
Can employees opt out of audiometric testing?
No. OSHA's standard requires the employer to make testing available, and the employee is expected to participate. If an employee refuses, document the refusal in writing. Your obligation is to offer and arrange the test. An employee who keeps refusing creates a liability and documentation problem for you, though OSHA doesn't spell out a penalty mechanism aimed at employee refusal.
Do I need to pay employees for time spent getting audiograms?
Yes. Under 29 CFR 1910.95(k), audiometric testing must be provided at no cost to employees, and OSHA's position is that time spent in required medical surveillance is compensable work time. Travel time to a testing location and the time being tested both count as hours worked under the Fair Labor Standards Act.
What if an employee brings in their own audiogram from their personal doctor?
OSHA lets an employee get their own audiogram from an outside physician or audiologist, and you must accept it as a valid baseline or annual test if it meets the standard's technical requirements: proper calibration, a quiet test environment, and the correct frequencies. You still have to review the results and take the required follow-up if an STS shows up.
How loud is 85 dB(A) in practical terms?
85 dB(A) is roughly a running lawn mower or a busy road heard from the sidewalk. In shops, metal grinding, angle grinders, pneumatic impact wrenches, and industrial saws typically run 95 to 110 dB(A) at the operator's ear. Most production environments with power tools clear the 85 dB(A) action level without much trouble.
Does wearing hearing protection remove my employees from the audiometric testing program?
No. If the underlying exposure without protectors sits at or above 85 dB(A) TWA, employees stay in the hearing conservation program, annual audiograms and all, no matter how consistently and correctly they wear protection. The protectors cut the damage. They don't cut the need for monitoring.
What happens if an employee's hearing loss shows up on the audiogram but they say it's from hunting or concerts?
Off-the-job noise can absolutely contribute, and OSHA acknowledges this when you're determining an STS. You can document that the employee reported outside exposures. But unless a physician finds the STS is entirely non-work-related, you still follow up per the standard. Age correction tables in Appendix F can also be applied. OSHA doesn't auto-exempt STS findings just because of off-the-job noise.
How do I find a qualified audiometric testing provider near my shop?
Mobile testing companies serve most metro areas and plenty of rural industrial zones. Search 'occupational audiometric testing' or 'industrial audiometry services' for your region. Your workers' comp carrier may have referral resources. The American Speech-Language-Hearing Association (ASHA) directory lists certified audiologists. Confirm the vendor documents audiometer calibration and that a supervising audiologist or physician reviews results.
Is there a maximum noise level at which OSHA requires workers to be removed from the area?
OSHA doesn't require automatic removal off a single noise reading. The standard works through TWA limits (the 90 dB(A) PEL) and controls. When the TWA exceeds 90 dB(A), feasible engineering and administrative controls come first. If those still can't get exposure below the PEL, hearing protectors step in, and the hearing conservation program applies from the 85 dB(A) action level.
What engineering controls does OSHA expect before just handing out earplugs?
29 CFR 1910.95(b)(1) says that when employees are exposed at or above the PEL, feasible engineering and administrative controls come first. Engineering controls include enclosures, barriers, vibration dampening, and equipment substitution. Administrative controls include rotating workers to shorten individual exposure time. Only when those don't cut exposure enough do hearing protectors come in as a supplement, not a first resort.
Does the audiometric testing requirement apply to office workers in the same building as a loud shop?
Only if their measured TWA exposure hits 85 dB(A) or more. An office worker who spends the day in a quiet space and crosses the shop floor now and then may have a TWA well under the action level. Measure before you assume. The requirement follows the person's actual exposure, not the job title or where the desk sits.
What OSHA forms or paperwork are specific to the hearing conservation program?
OSHA has no standard form for audiometric records. The rule specifies what each audiogram record must contain: employee name, job classification, date of audiogram, examiner name and certification, date of last audiometer calibration, and the employee's most recent noise exposure measurement. Most testing vendors hand you records that include all of it. You keep them, and the format is up to you.
Can OSHA cite me for a hearing conservation violation during a general inspection if noise wasn't the reason for the visit?
Yes. Compliance officers run wall-to-wall inspections and will cite any violation they see or turn up, whatever the original trigger. A complaint about machine guarding can end in citations for missing audiograms once the officer notices loud machinery and asks for records. That's one reason to run the full program even when no inspection is on the calendar.
Sources
- OSHA, 29 CFR 1910.95 Occupational Noise Exposure (full standard text): Action level of 85 dB(A) TWA, baseline audiogram timing, annual audiogram requirement, STS definition of 10 dB average at 2000/3000/4000 Hz, hearing protector requirements, training content requirements, and record retention periods.
- NIOSH, Criteria for a Recommended Standard: Occupational Noise Exposure (DHHS Publication No. 98-126): NIOSH recommends a 3-dB exchange rate and a recommended exposure limit (REL) of 85 dB(A) as an 8-hour TWA, stricter than OSHA's current 5-dB exchange rate.
- OSHA, On-Site Consultation Program for Small Businesses: OSHA's On-Site Consultation Program provides free safety and health consultations to small businesses, including noise monitoring and hearing conservation program assistance.
- OSHA, Recording Criteria for Cases Involving Occupational Hearing Loss (29 CFR 1904.10): An STS is recordable on the OSHA 300 log if work-related and the total hearing level is 25 dB or more above audiometric zero at 2000, 3000, and 4000 Hz in the affected ear.
- OSHA, Hearing Conservation (OSHA 3074 Booklet): OSHA recommends deriving real-world hearing protector attenuation by subtracting 7 from the labeled NRR and dividing by 2, because field performance is consistently below lab-tested NRR values.
- OSHA, Training Guidelines for the Hearing Conservation Amendment (Federal Register Vol. 48, No. 46, March 8, 1983): OSHA's training guidelines specify that hearing conservation training must cover effects of noise on hearing, purpose and use of hearing protectors, and purpose and procedures of audiometric testing.
- OSHA, Penalties (Federal Civil Penalties Inflation Adjustment Act): OSHA's maximum penalty for a serious violation is $16,550 per violation as of 2024 federal civil penalty adjustments.
- OSHA, Commonly Used Statistics and Frequently Cited Standards (General Industry): Noise and hearing conservation violations are among the regularly cited general industry standards; common deficiencies include missing baselines, no STS follow-up, and inadequate training documentation.
- OSHA, State Plans page: Twenty-two states and two territories operate OSHA-approved state plans covering private employers; state plans must be at least as effective as federal OSHA.
- California Department of Industrial Relations, Cal/OSHA Title 8 Section 5097 (Hearing Conservation): Cal/OSHA's hearing conservation standard includes additional provisions beyond federal OSHA's 1910.95, including specific physician review requirements for audiogram evaluation.
- OSHA, Hearing Conservation Amendment Final Rule (48 FR 9738, March 8, 1983): The Hearing Conservation Amendment became effective in 1983 and added structured audiometric testing, training, and recordkeeping requirements to the pre-existing noise exposure standard.
- BLS, Survey of Occupational Injuries and Illnesses (Occupational Hearing Loss data): BLS data on occupational injuries and illnesses includes occupational hearing loss cases tracked through the OSHA recordkeeping system.