Last updated 2026-07-11

TL;DR
Small auto recyclers must manage lead-acid battery acid as hazardous waste under EPA's RCRA rules and follow OSHA's Hazard Communication and PPE standards when handling it. Most shops qualify as Very Small Quantity Generators, which cuts paperwork sharply. But one bad move, like draining acid onto gravel, can trigger full generator status and EPA enforcement. Know your thresholds before you act.
What makes battery acid a regulated hazardous waste at an auto recycler?
Sulfuric acid, the electrolyte in every lead-acid car battery, is a hazardous waste under the Resource Conservation and Recovery Act (RCRA). Spent battery acid exhibits the characteristic of corrosivity: a pH at or below 2.0 or above 12.5, per 40 CFR 261.22 [1]. Drain a battery, let the acid leave the casing with no plan to reclaim it, and it becomes a hazardous waste subject to federal and state regulation the moment it hits the container.
The battery casing itself is a separate story. Whole spent lead-acid batteries are conditionally exempt from RCRA when sent for reclamation, under 40 CFR 266.80 [2]. That exemption disappears if the battery is cracked, you drain the acid separately, or you store batteries in a way that signals disposal rather than reclamation. Most auto recyclers should be returning whole batteries to a distributor or a permitted smelter. The second you start breaking them open to pull acid or scrap lead, you're outside the exemption.
Lead in the battery plates is also a RCRA-regulated hazardous waste (waste code D008, the toxicity characteristic for lead) if it ends up as discarded material rather than going to a legitimate reclaimer [3]. So the rule of thumb is simple. Keep batteries whole, return them through a documented chain to a reclaimer, and never let acid drain freely onto soil, a floor drain, or a dumpster.
What is your generator status and why does it change everything?
RCRA sorts hazardous waste generators into three categories, and the one you land in decides almost every compliance requirement you face: recordkeeping, storage time limits, manifests, emergency planning, and training [4]. Get your category right and the rest of the rules fall into place. Get it wrong and you're either doing too much paperwork or breaking the law.
The thresholds, updated by EPA's 2016 Generator Improvements Rule (effective 2018), are:
| Generator Category | Hazardous Waste Generated Per Month | Key Requirements |
|---|---|---|
| Very Small Quantity Generator (VSQG) | 100 kg or less (about 220 lbs) | No manifest, no time limit on storage if sent to approved facility, basic emergency planning |
| Small Quantity Generator (SQG) | 101 to 1,000 kg | 270-day storage limit, manifest required, biennial report in some states, emergency coordinator |
| Large Quantity Generator (LQG) | More than 1,000 kg | 90-day storage limit, full contingency plan, employee training program, biennial report |
For a typical small auto recycler, 100 kg of sulfuric acid is roughly 7 to 10 gallons, depending on concentration (standard battery acid runs about 1.26 g/mL) [5]. A shop pulling batteries from 20 to 30 cars a week is almost certainly a VSQG if batteries leave whole, because the acid never technically becomes a waste. Drain those batteries on-site, though, and even a modest operation can hit SQG thresholds fast.
Here's what trips up small recyclers. Generator status is recalculated every calendar month based on how much waste you actually generate that month. A slow month doesn't erase a heavy one in EPA's eyes if you already shipped a manifest. Track your numbers month by month, not on average.
What are the specific storage rules for battery acid you've already drained?
Once you've drained battery acid into containers on your property, the clock and the containment rules start running. VSQGs have no federally mandated storage time limit, but they must send waste to a RCRA-permitted facility, a facility regulated under RCRA, or another VSQG [4]. You cannot sit on it forever on the theory that "we'll deal with it later." States often impose stricter limits, and authorized RCRA states like California, Washington, and Minnesota run programs tougher than the federal baseline.
For SQGs, the 270-day limit is firm. For LQGs, it's 90 days. Containers have to be in good condition, kept closed except when adding or removing waste, labeled with "Hazardous Waste" plus the contents and accumulation start date, and stored to prevent releases to the environment [4].
Container material matters more than people think. Sulfuric acid (pH near 1) eats through standard steel drums over time. High-density polyethylene (HDPE) carboys or drums rated for corrosive materials are the right call. Don't store acid containers near reactive materials, including the lead plates from the batteries themselves.
Secondary containment is not federally required for VSQG storage. But it's an OSHA requirement if workers could be exposed to a spill (more on that below), and many state programs require it anyway. A simple bermed concrete pad under your battery storage area is cheap. There's no good reason to skip it. One spill into a floor drain that reaches a storm sewer can produce a Superfund referral. That's not a hypothetical.
How does the Universal Waste rule affect auto recycler battery management?
The Universal Waste program under 40 CFR Part 273 covers certain widely generated hazardous wastes, including batteries, to simplify how you manage them [6]. Here's the catch for auto recyclers: the Universal Waste battery rule covers most battery types (nickel-cadmium, lithium, alkaline), but lead-acid batteries have their own separate provision under 40 CFR 266.80, not Part 273 [2].
So for lead-acid batteries specifically, you're back on the 266.80 reclamation exemption, not Universal Waste. The practical difference: Universal Waste batteries get relaxed labeling and storage rules because they're presumed headed to recycling. Lead-acid batteries under 266.80 earn the exemption only if they're actually being reclaimed, you can document it, and they're managed to avoid releases.
Modern auto recyclers see other battery types too, like the lithium-ion packs from hybrid or EV vehicles, and the regulatory picture there is different. Lithium-ion batteries are not lead-acid, and their waste management falls under Universal Waste rules or RCRA characteristic waste rules depending on chemistry and state. EV battery packs can be large, heavy, and carry thermal runaway risks that a standard 12-volt battery never does. If you're starting to take in hybrid or EV vehicles, treat that as a fresh regulatory review, not a simple extension of what you already do.
What does OSHA require for workers who handle battery acid?
OSHA's rules on battery acid handling flow from several standards, not one. The main ones are Hazard Communication (29 CFR 1910.1200), Personal Protective Equipment (29 CFR 1910.132 and 1910.138), and the general duty clause (Section 5(a)(1) of the OSH Act) for hazards without a specific standard [7].
Hazard Communication (HazCom) requires sulfuric acid to appear in your workplace chemical inventory, a current Safety Data Sheet (SDS) on file and accessible to workers, and properly labeled containers [8]. The SDS for sulfuric acid will tell you it's a GHS Category 1 corrosive with serious acute toxicity. Workers need to know what that means before they ever pick up a container. That's not optional. It's an explicit HazCom requirement. You can see what a full hazard communication program looks like in a shop setting.
On PPE, the acid in a standard 12-volt car battery runs roughly 30 to 50 percent sulfuric acid by weight [5]. At that concentration, skin contact causes rapid chemical burns, and a splash to the eyes can blind someone in minutes. OSHA 29 CFR 1910.138 requires hand protection matched to the specific chemical hazard, which means nitrile gloves at minimum and thicker neoprene or PVC gloves for anyone handling open containers of acid. Add a face shield (safety glasses alone won't cut it) any time there's a real splash risk, an acid-resistant apron, and chemical-splash-rated footwear. The PPE assessment has to be written down under 29 CFR 1910.132(d)(2).
An emergency eyewash station within 10 seconds of travel from any acid handling area is required under ANSI Z358.1 and expected by OSHA under the general duty clause. Hot water only is not acceptable. Tepid water (60 to 100 degrees F) is the ANSI standard, and a 10-minute continuous flow is the minimum.
What written programs does OSHA require a small auto recycler to have?
Most small auto recyclers sit in SIC code 5015 (Motor Vehicle Parts, Used), which puts them under OSHA's general industry standards (29 CFR Part 1910). The written programs you almost certainly need:
Hazard Communication Program. Required by 29 CFR 1910.1200(e) for any employer with hazardous chemicals in the workplace. Must include your chemical inventory, SDS management process, container labeling procedures, and training documentation. Battery acid, used oil, antifreeze, refrigerants, and brake fluid are all on the list [8].
Written PPE Hazard Assessment. Required by 29 CFR 1910.132(d) any time you require workers to wear PPE. The assessment must be documented in writing and certified by a responsible person.
Emergency Action Plan. Required by 29 CFR 1910.38 for employers with more than 10 employees. Even under 10 people, you need a plan for chemical spills and fires. With battery acid and used oil on site, a spill response procedure isn't optional.
Lockout/Tagout Program. Required by 29 CFR 1910.147 for any shop using equipment with hazardous energy. Nearly every auto recycler has hydraulic lifts, shredders, or crushing equipment that qualifies. Read more about lockout tagout requirements if your program isn't in place.
For a shop that wants to build these without hiring a consultant, SafetyFolio's safety program generator walks you through each required element in about 15 minutes and produces a document you can actually hand to an OSHA inspector.
Worth knowing: OSHA does inspect auto recyclers. The agency's Site-Specific Targeting program uses injury and illness data to prioritize inspections, and BLS data shows automotive recycling (NAICS 423140) has injury rates meaningfully above the average for retail trade [9]. You are not flying under the radar.
How do you handle used oil, antifreeze, and other fluids alongside battery acid?
Battery acid gets most of the regulatory attention, but auto recyclers generate a steady stream of other regulated wastes: used oil, used antifreeze, refrigerants (freon from A/C systems), used brake fluid, transmission fluid, and gasoline or diesel from fuel tanks. Each has its own rules, and mixing them is the fastest way to make a small problem into a big one.
Used oil has its own regulatory program under 40 CFR Part 279, distinct from RCRA hazardous waste rules [10]. If used oil isn't mixed with hazardous waste and is headed for recycling or re-refining, it's regulated as "used oil" rather than hazardous waste, which is far less burdensome. Keep it in labeled tanks or containers, prevent mixing with solvents or other hazardous waste (which can turn the whole batch into hazardous waste), maintain records of off-site shipments, and use a registered used oil transporter.
Antifreeze (ethylene glycol) is not federally listed as a hazardous waste, but it can exhibit toxicity characteristics when contaminated with heavy metals. Many states regulate it separately. And it's sweet-tasting, so it's attractive to animals and toxic to them. Storage and disposal matter even where your state doesn't require much.
Refrigerants are regulated under Section 608 of the Clean Air Act, not RCRA, and technicians who recover refrigerant from vehicles must be certified under EPA Section 608 rules [12]. You cannot vent refrigerants to the atmosphere. This certification is separate from anything OSHA requires, and EPA audits are real.
The simplest operational model for most small recyclers: designate separate, labeled collection tanks for each fluid type, use a licensed transporter or used oil hauler for pickup, and keep a one-page log of what goes out, when, and to whom. That log is the single most useful document you'll have if an inspector shows up.
What are the penalties for getting battery acid disposal wrong?
EPA civil penalties for RCRA violations run up to $70,117 per day per violation as of the 2023 inflation adjustment [11]. That number applies to each separate violation. So a small recycler storing unlabeled acid containers past the time limit while also missing the emergency planning requirement could face penalties stacking from several counts at once.
EPA typically applies a penalty gravity matrix that weighs the seriousness of the violation, the violator's compliance history, and ability to pay. Small businesses with no prior violations that self-disclose and fix problems fast tend to fare better. EPA's Small Business Compliance Policy formally allows penalty reductions for businesses with fewer than 100 employees who find and correct violations before an inspection [11].
OSHA penalties are separate. As of 2024, serious violations run up to $16,131 per violation, and willful or repeat violations run up to $161,323 [7]. A missing written PPE hazard assessment plus a worker handling battery acid without proper gloves is exactly the pairing that produces a serious citation on a programmed inspection.
State penalties can beat federal minimums if the state runs an authorized RCRA program. California's penalties, for one, are often well above the federal baseline.
Fines aren't the worst of it. If battery acid migrates to groundwater from a badly managed storage area, cleanup costs dwarf any regulatory fine. The average cost of a RCRA corrective action cleanup is hard to pin down (EPA has not published a clean per-site average), but the agency's own case histories document individual site cleanups running from the hundreds of thousands into the millions.
What records do you need to keep and for how long?
RCRA recordkeeping requirements vary by generator status, but every generator should hold onto certain documents. Here's the short version:
| Record Type | Who Needs It | Retention Period |
|---|---|---|
| Waste determination records (how you determined a waste is or isn't hazardous) | All generators | 3 years |
| Uniform Hazardous Waste Manifests | SQG and LQG | 3 years |
| Land Disposal Restriction notifications | SQG and LQG | 3 years after waste sent |
| Exception reports (manifest not returned) | SQG and LQG | 3 years |
| Biennial reports | LQG | 3 years |
| Training records | SQG and LQG | 3 years, LQG keeps for active employee life plus 3 years |
VSQGs have no specific RCRA manifest or report requirement at the federal level. Smart practice is to keep a simple log anyway: date, waste type, approximate quantity, destination facility, and transporter name. If EPA ever questions whether you crossed into SQG territory in a given month, that log is the difference between a fast resolution and a drawn-out investigation.
For OSHA, the Hazard Communication standard requires you to keep SDSs for all hazardous chemicals in the workplace and make them accessible to employees on every shift [8]. Training records showing who was trained, when, and on what are not required to be in writing by OSHA's HazCom rule, but they're essential evidence in any inspection or citation appeal. Keep them.
Injury and illness records under OSHA's 29 CFR 1904 recordkeeping rule apply if you have 10 or more employees. A worker who suffers a chemical burn from battery acid is a recordable incident. Learning how to complete a proper incident report matters more than most small businesses realize until they need one.
How should you train workers to handle battery acid safely?
OSHA's HazCom standard requires training on hazardous chemicals at initial assignment, when new chemicals are introduced, and whenever there's reason to believe workers don't understand the hazards [8]. "Training" means something specific here: workers must understand the GHS hazard categories and label elements, know how to read an SDS, and know how to protect themselves.
For battery acid, training should cover what sulfuric acid does to skin and eyes (chemical burns within seconds at full concentration), how to put on and take off PPE in the right order (gloves off last, wash hands before touching your face), what to do if acid splashes (flush with water for 15 to 20 minutes, call for medical help, don't wait to see if it hurts), and where the eyewash station is and how to use it.
The SDS for sulfuric acid is a document you want workers to actually read, more than sign that they received. The hcl safety data sheet article on SafetyFolio explains how to read a corrosive chemical SDS if your team needs a primer.
Beyond chemical handling, auto recyclers should have OSHA-level safety training covering the full job. OSHA training requirements for general industry apply here, and for shop supervisors or safety leads, an OSHA 30 card shows a level of general industry competency that also looks good if OSHA ever asks about your safety culture.
One practical tip: run a tabletop drill on a chemical spill scenario once a year. Walk through where the spill kit is, how to call 911 if someone gets acid in their eyes, and who calls the state environmental agency if you have a release. A drill costs an hour of labor. An unplanned release with no response plan costs far more.
Are there any state-level rules that go beyond federal requirements?
Yes, and this is where small auto recyclers most often get blindsided. EPA has authorized 46 states plus the District of Columbia and 3 territories to run their own RCRA hazardous waste programs. Authorized state programs must be at least as stringent as federal rules, and they often go further [4].
California (CalRecycle and DTSC) is the strictest. California classifies used antifreeze as a hazardous waste, sets lower quantity thresholds that can push small recyclers into higher generator categories, and its Universal Waste rules cover items not covered federally. California also enforces stormwater permits (NPDES) hard on auto recyclers. The vehicle recycling stormwater permit program is a genuine compliance concern for any California shop [4].
Washington State requires used oil handlers to register with the Department of Ecology and sets specific containment requirements for outdoor fluid storage. Michigan, Oregon, and New York each have state-specific provisions that change the federal baseline in ways that matter for auto recyclers.
For OSHA, 29 states and 2 territories run their own OSHA-approved State Plans. State plans must be at least as effective as federal OSHA, but they can exceed it [7]. California's Cal/OSHA, for example, has battery charging area requirements (Title 8 CCR 5480) more specific than federal OSHA on ventilation and PPE.
The only reliable way to know your state's rules is to contact your state environmental agency directly, or use EPA's RCRA state program lookup. Do it before assuming federal rules are your ceiling.
What does a practical compliance checklist look like for a small auto recycler?
This isn't a substitute for a full program review, but it's a working starting point. Walk your shop against these items every quarter.
Battery storage and disposition
- Whole spent lead-acid batteries stored upright in a clearly labeled area, not cracked or leaking
- Documentation showing batteries go to a licensed reclaimer or distributor
- No batteries stored outdoors directly on soil without secondary containment
Waste determination
- Written record showing how you determined each waste stream is hazardous or not
- Monthly quantity tracking if you drain batteries on-site
- Generator status confirmed for the current calendar year
Fluid management
- Separate labeled tanks for used oil, antifreeze, and battery acid (if drained)
- No mixing of used oil with solvents or hazardous waste
- Licensed transporter records for all waste sent off-site
OSHA documentation
- Current HazCom program and chemical inventory including battery acid
- SDS file accessible on every shift
- Written PPE hazard assessment completed and signed
- Emergency eyewash station tested weekly (log kept) and within 10 seconds of acid handling areas
- Emergency Action Plan posted if you have more than 10 employees
- Lockout/Tagout written program in place for all energy-isolating equipment
Training
- HazCom training documented for all current employees
- PPE training documented
- Spill response drill completed in the last 12 months
If more than three items on this list are missing, you're not in a "minor gaps" situation. You're in a "meaningful violation risk" situation. A written program covering HazCom, PPE, emergency action, and lockout/tagout can be assembled faster than most shop owners expect.
Frequently asked questions
Does my auto recycler need an EPA ID number for battery acid?
VSQGs do not need an EPA ID number at the federal level. SQGs and LQGs must obtain one before they can transport or dispose of hazardous waste. If you generate more than 100 kg of hazardous waste in any calendar month, apply for an EPA ID through your state environmental agency before moving any waste off-site. Many states require VSQGs to notify as well, so check your specific state rules.
Can I pour battery acid down the drain if I neutralize it first?
Maybe, but not without checking. Neutralized sulfuric acid (brought to a pH between 6 and 9) may be acceptable to some publicly owned treatment works (POTWs), but you must contact your local POTW and get written approval first. Discharging without approval violates the Clean Water Act. Some POTWs flatly prohibit it. Never assume drain disposal is fine. Get it in writing from the facility.
What PPE is required for someone handling battery acid at an auto recycler?
At minimum: neoprene or PVC chemical-resistant gloves, a full face shield (more than safety glasses), an acid-resistant apron, and chemical-resistant footwear. For open containers of concentrated sulfuric acid, rubber boots and full-body coverage are appropriate. The PPE selection must be documented in a written hazard assessment under OSHA 29 CFR 1910.132(d). Nitrile gloves are fine for brief contact but not for sustained handling of full-strength acid.
How long can I store hazardous battery acid waste on-site?
VSQGs have no federal time limit but must send waste to an approved facility. SQGs may store for up to 270 days. LQGs are limited to 90 days. Storage beyond these limits without a permit counts as treatment, storage, or disposal, which requires a RCRA permit and triggers much more serious enforcement exposure. States may set shorter limits; check your state environmental agency's rules.
What happens to my generator status if I have one unusually large month of battery acid waste?
Generator status is determined month by month. If you generate more than 100 kg of hazardous waste in a single month, you're an SQG for that month, regardless of what you generated in other months. SQG requirements, including manifesting and the 270-day storage limit, apply to all the waste you generated that month. Document the situation carefully and make sure any waste from that month was managed under SQG rules.
Are lithium-ion EV batteries regulated the same way as lead-acid batteries?
No. Lead-acid batteries have a specific exemption under 40 CFR 266.80 when sent for reclamation. Lithium-ion batteries fall under Universal Waste rules (40 CFR Part 273) or RCRA characteristic waste rules depending on their condition and state. EV battery packs also carry thermal runaway and high-voltage hazards that require separate safety protocols well beyond standard battery handling. Treat EV batteries as a distinct regulatory category needing its own review.
Do I need a Spill Prevention, Control, and Countermeasure (SPCC) plan?
SPCC plans under 40 CFR Part 112 are required if you store more than 1,320 gallons of oil above ground in aggregate, or more than 42,000 gallons below ground. Many auto recyclers cross the threshold once you count all used oil storage tanks together. SPCC plans are separate from RCRA requirements and enforced by EPA under the Clean Water Act. If you're near or over the threshold, consult your state environmental agency.
What OSHA standards apply to charging lead-acid batteries at an auto recycler?
OSHA's 29 CFR 1910.178(g) covers industrial battery charging, requiring adequate ventilation to prevent hydrogen gas accumulation (hydrogen is explosive above 4% concentration in air), PPE to prevent acid splash, and charging areas protected from open flames or sparks. Eye wash facilities must be in the charging area. Federal OSHA's general duty clause covers any gaps. California's Title 8 CCR 5480 has more detailed state requirements.
What training does OSHA require for auto recycler employees who work with battery acid?
OSHA's HazCom standard (29 CFR 1910.1200) requires training on hazardous chemicals before initial assignment and when new chemicals are introduced. Training must cover GHS label elements, how to read an SDS, and protective measures including PPE. PPE training is separately required under 29 CFR 1910.132(f). Training must be in a language and vocabulary the employee understands. Documenting training is strongly advised even though the standard doesn't mandate a specific format.
Can I be inspected by both OSHA and EPA as a small auto recycler?
Yes, and both agencies operate independently. OSHA inspects for worker safety violations; EPA inspects for environmental compliance. A single incident, like a battery acid spill, can trigger both an OSHA citation for inadequate PPE or emergency response and an EPA enforcement action for improper waste management. In states with state OSHA plans, the state agency handles OSHA enforcement. Both agencies can and do inspect auto recyclers without advance notice.
Does used antifreeze from drained vehicles count toward my hazardous waste generator threshold?
Possibly. Used antifreeze is not a federally listed hazardous waste, but it may exhibit the toxicity characteristic (D018 for benzene or D008 for lead) if contaminated, making it a characteristic hazardous waste that counts toward your monthly threshold. Have a sample tested if you generate significant quantities. Many states regulate used antifreeze separately regardless of federal classification. Don't mix it with used oil unless you want the whole combined volume treated as used oil at best, or hazardous waste at worst.
What is the difference between the RCRA exemption for lead-acid batteries and the Universal Waste rule?
Lead-acid batteries sent for reclamation are exempt from RCRA under 40 CFR 266.80, not the Universal Waste rule (40 CFR Part 273). The Universal Waste rule covers nickel-cadmium, lithium, and most other battery types. Both pathways are easier than full RCRA compliance, but they carry different requirements. The 266.80 exemption requires batteries to actually go to a legitimate reclaimer. Universal Waste requires proper labeling and management at collection points.
What do I do if battery acid spills onto soil at my facility?
Stop the source, contain the spill with absorbent materials compatible with acid (not organic materials that can react), and keep it from reaching floor drains or storm drains. Contaminated soil may be a RCRA hazardous waste requiring disposal through a licensed hazardous waste transporter. If the release reaches surface water or a drain connected to waters of the U.S., you may have reporting obligations under the Clean Water Act and CERCLA. Contact your state environmental agency.
How do I find a licensed hazardous waste transporter and disposal facility for battery acid?
Use EPA's RCRAInfo database to find permitted treatment, storage, and disposal facilities in your state. Many battery distributors and auto parts wholesalers run take-back programs for lead-acid batteries that handle transport and reclamation. For drained acid specifically, search for corrosive waste disposal services or contact your state environmental agency for a list of licensed transporters. Always verify transporter registration before handing over waste.
Sources
- EPA, 40 CFR Part 261, Identification and Listing of Hazardous Waste: Waste with a pH at or below 2.0 or above 12.5 exhibits the corrosivity characteristic under 40 CFR 261.22
- EPA, 40 CFR Part 266 Subpart G, Standards for the Management of Spent Lead-Acid Batteries Being Reclaimed: Spent lead-acid batteries being reclaimed are conditionally exempt from RCRA under 40 CFR 266.80
- EPA, Defining Hazardous Waste: Listed, Characteristic and Mixed Radiological Wastes: Lead in discarded battery plates may exhibit the toxicity characteristic, waste code D008, under RCRA
- EPA, Hazardous Waste Generators, RCRA Generator Categories: RCRA sorts generators into VSQG, SQG, and LQG categories with distinct requirements; authorized states may be more stringent
- OSHA, Occupational Chemical Database, Sulfuric Acid: Standard battery electrolyte is roughly 30 to 50 percent sulfuric acid by weight with a density near 1.26 g/mL
- EPA, 40 CFR Part 273, Standards for Universal Waste Management: Universal Waste rules cover batteries including nickel-cadmium and lithium but lead-acid batteries are governed under 40 CFR 266.80 separately
- OSHA, Penalties, OSHA.gov: OSHA serious violation penalties up to $16,131 per violation and willful or repeat violations up to $161,323 as of 2024
- OSHA, 29 CFR 1910.1200, Hazard Communication Standard: HazCom requires employers to maintain SDSs, label containers, maintain a chemical inventory, and train workers on hazardous chemicals
- Bureau of Labor Statistics, Survey of Occupational Injuries and Illnesses, Industry Data: BLS occupational injury and illness data by NAICS industry code including auto parts used dealers (NAICS 423140)
- EPA, 40 CFR Part 279, Standards for the Management of Used Oil: Used oil not mixed with hazardous waste and destined for recycling is regulated under 40 CFR Part 279, not as RCRA hazardous waste
- EPA, Enforcement Civil Penalties and Small Business Compliance Policy: RCRA civil penalties run up to $70,117 per day per violation (2023 inflation adjustment); EPA's Small Business Compliance Policy allows reductions for firms under 100 employees who self-correct
- EPA, Section 608 Refrigerant Management Program: Technicians who recover refrigerant from vehicles must be certified under EPA Section 608; venting refrigerants to the atmosphere is prohibited